• 86-0372-3669559
  • nana1@kayo-tech.cn
  • Company Details

Anyang Kayo Amorphous Technology Co.,Ltd.

All
  • All
  • Title
All
  • All
  • Title
Home> Industry Information> How to connect current transformer and reactive power meter

How to connect current transformer and reactive power meter

April 20, 2021

Current Transformer connection is not complicated, only four wiring forms.
1. It is the wiring form of a single current transformer.
Can only reflect the situation of single-phase current. It is applicable to the need to measure the balance of one-phase current or three-phase load. When one phase is measured, the three-phase condition can be known, and most of the ammeters are connected.
2, three-phase complete star wiring and delta wiring form.
The three-phase current transformer can accurately understand the three-phase load changes in time, and is often used in transformer differential protection wiring. Only use three-phase complete star-wired current acquisition for watt-hour meters in a direct neutral grounding system. The three-phase three-relay connection method can not only react to various types of phase-to-phase short-circuits, but also can react to single-phase ground short-circuits. Therefore, this wiring method is used for the protection of phase short-circuit protection and single-phase ground short-circuit in the neutral point direct grounding system.
3, two-phase incomplete star wiring form.
It is used most in practical work. It saves one current transformer and uses the combined current of phase A and phase C to form an inverting phase B current. The two-phase dual-relay connection method can respond to phase-to-phase short circuits, but it cannot fully respond to a single-phase ground short circuit, so it cannot be used for single-phase ground protection. This wiring method is used for neutral point ungrounded systems or arc suppression coil grounding systems for phase-to-phase short-circuit protection.
4, two phase difference current wiring form.
It is also used only in three-phase three-wire circuits. The neutral point is not grounded, and there is no neutral line. The advantage of this type of connection is that it not only saves a current transformer, but also uses a relay to reflect the various types of three-phase circuits. Phase-to-phase short-circuit faults, that is, three-phase overcurrent protection with minimal relays, save investment. However, when the failure mode is different, the sensitivity is different. This type of wiring is often used for phase-to-phase short-circuit protection in distribution networks up to 10kV. Due to the low sensitivity of this type of protection, modern times have rarely been used.

The above is the How to connect current transformer and reactive power meter we have listed for you. You can submit the following form to obtain more industry information we provide for you.

You can visit our website or contact us, and we will provide the latest consultation and solutions

Share to:

Send Inquiry

Home> Industry Information> How to connect current transformer and reactive power meter

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send